<location>Encoder 1: Reference point coordinate not in the permissible
range
Message
%1
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The reference point coordinate received when adjusting the encoder via connector input CI:p2599 lies
outside the half of the encoder range and cannot be set as current axis position. The maximum per-
missible value is displayed in the supplementary information.
Remedy:
Set the reference point coordinate less than the value from the supplementary information.
See also: p2598 (EPOS reference point coordinate, signal source)
207558
<location>Encoder 2: Reference point coordinate not in the permissible
range
Message
%1
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The reference point coordinate received when adjusting the encoder via connector input CI:p2599 lies
outside the half of the encoder range and cannot be set as current axis position. The maximum per-
missible value is displayed in the supplementary information.
Remedy:
Set the reference point coordinate less than the value from the supplementary information.
See also: p2598 (EPOS reference point coordinate, signal source)
207559
<location>Encoder 3: Reference point coordinate not in the permissible
range
Message
%1
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The reference point coordinate received when adjusting the encoder via connector input CI:p2599 lies
outside the half of the encoder range and cannot be set as current axis position. The maximum per-
missible value is displayed in the supplementary information.
Remedy:
Set the reference point coordinate less than the value from the supplementary information.
See also: p2598 (EPOS reference point coordinate, signal source)
207560
<location>Drive encoder: Number of pulses is not to the power of two
Message
Encoder data set: %1
value:
Drive object:
SERVO, VECTOR
Reaction:
OFF2 (IASC/DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
For rotary absolute encoders, the pulse number in p0408 must be to the power of two.
Fault value (r0949, interpret decimal):
The fault value includes the encoder data set number involved.
Remedy:
- check the parameterization (p0408, p0404.1, r0458.5).
- if required, upgrade the Sensor Module firmware.
207561
<location>Drive encoder: Number of multiturn pulses is not to the power
of two
Message
Encoder data set: %1
value:
Drive object:
SERVO, VECTOR
Reaction:
OFF2 (IASC/DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
© Siemens AG 2009 All Rights Reserved