Siemens Sinumerik 840D sl Diagnostic Manual page 511

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
61505
[Channel %1: ] Block %2: retraction path < 1mm
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE420
Remedy:
Increase retraction path
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61506
[Channel %1: ] Block %2: infeed path < 1mm
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE420
Remedy:
Increase infeed path
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61507
[Channel %1: ] Block %2: safety clearance < 1mm
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61508
[Channel %1: ] Block %2: Incorrect default setting for shoulder position
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61509
[Channel %1: ] Block %2: Incorrect default setting for dresser position
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61510
[Channel %1: ] Block %2: Test run feed is active
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE410, CYCLE411, CYCLE413,
CYCLE415, CYCLE420
Remedy:
Switch off test run feed
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61511
[Channel %1: ] Block %2: Incorrect shoulder position or tool edge D1/D2
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-511