Overview of Alarms
NCK alarms
Definitions:
More machine axes have been defined through the MD20070 $MC_AXCONF_MACHAX_USED than
are allowed in the system.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. The sum of all axes that have been con-
figured through the channel-specific MD20070 $MC_AXCONF_MACHAX_USED, must not exceed
the maximum number of axes (dependent on configuration -> option, basic version: 4 axes).
Program Con-
Switch control OFF - ON.
tinuation:
8020
Option 'activation of more than %1 channels' not set
Parameters:
%1 = Number of channels
Definitions:
A 2nd channel has been indicated but the corresponding option does not exist.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
In the system-specific MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP, reduce the number of
channels to 1 or retrofit the option for a 2nd channel.
Program Con-
Switch control OFF - ON.
tinuation:
8021
Option 'activation of more than %1 mode groups' not set
Parameters:
%1 = Number of mode groups
Definitions:
The option for the number of mode groups is not compatible with the activated mode group.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Add option for more mode groups. Activate fewer mode groups.
Program Con-
Switch control OFF - ON.
tinuation:
8022
Option 'activation of more than %1KB SRAM' not set
Parameters:
%1 = Memory size
Definitions:
The option for memory extension does not correspond to the active SRAM.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Buy option
- Activate less SRAM
Program Con-
Switch control OFF - ON.
tinuation:
8023
Option 'Activation of more than %1 KB PLC user memory' not set
Parameters:
%1 = Memory size
Definitions:
The option for the memory configuration does not correspond to the PLC user memory used.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Purchase option
- Use less PLC user memory
Program Con-
Switch control OFF - ON.
tinuation: