Overview of Alarms
NCK alarms
4630
Invalid handwheel module for handwheel %1
Parameters:
%1 = Handwheel module
Definitions:
For PROFIBUS/PROFINET only:
The reference in $MN_HANDWHEEL_MODULE to a corresponding entry in machine data array
$MN_HANDWHEEL_LOGIC_ADDRESS[] which is required for configuring PROFIBUS handwheels
is not available.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure the machine data MD11351 $MN_HANDWHEEL_MODULE for the corresponding PROFI-
BUS handwheel so that there is a valid reference to an entry in the machine data array MD11353
$MN_HANDWHEEL_LOGIC_ADDRESS[].
Program Con-
Switch control OFF - ON.
tinuation:
4631
Invalid handwheel slot for handwheel %1
Parameters:
%1 = Handwheel slot
Definitions:
For PROFIBUS/PROFINET only:
The handwheel slot for handwheel %1 requested through machine data $MN_HANDWHEEL_INPUT
is not available for PROFIBUS handwheels.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure machine date MD11352 $MN_HANDWHEEL_INPUT to a valid handwheel slot for the cor-
responding PROFIBUS handwheel.
Program Con-
Switch control OFF - ON.
tinuation:
4632
Logical PROFIBUS handwheel slot base address for handwheel %1 not
found
Parameters:
%1 = Handwheel number
Definitions:
For PROFIBUS/PROFINET only:
The logical basic address of the PROFIBUS handwheel slot in machine data array
$MN_HANDWHEEL_LOGIC_ADDRESS[] indexed in machine data $MN_HANDWHEEL_MODULE
was not found in the current STEP 7 hardware configuration.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Check if MD11351 $MN_HANDWHEEL_MODULE of the corresponding handwheel is correct. Check
if indexed logical base address of PROFIBUS handwheel slot in machine date array MD11353
$MN_HANDWHEEL_LOGIC_ADDRESS[] is correct.
Program Con-
Switch control OFF - ON.
tinuation:
4640
Invalid handwheel module for handwheel %1
Parameters:
%1 = Handwheel module
Definitions:
For ETHERNET only:
The handwheel module for handwheel %1 requested through MD11351
$MN_HANDWHEEL_MODULE is not available for ETHERNET handwheels. MD11351
$MN_HANDWHEEL_MODULE = 1 must always be set when configuring ETHERNET handwheels.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Set machine date MD11351 $MN_HANDWHEEL_MODULE = 1 for the corresponding handwheel.
Program Con-
Switch control OFF - ON.
tinuation:
4641
Invalid handwheel input for handwheel %1
Parameters:
%1 = Handwheel input
Definitions:
For ETHERNET only:
The handwheel input for handwheel %1 requested through MD11352 $MN_HANDWHEEL_INPUT is
not available for ETHERNET handwheels. A maximum of 6 handwheels can be configured.