44: Position actual value + limit value SLS1 / safety monitoring clock cycle.
45: Pos. act. val. - limit value SLS1 / safety monitoring clock cycle.
46: Pos. act. val. + limit value SLS2 / safety monitoring clock cycle.
47: Pos. act. val. - limit value SLS2 / safety monitoring clock cycle.
48: Pos. act. val. + limit value SLS3 / safety monitoring clock cycle.
49: Pos. act. val. - limit value SLS3 / safety monitoring clock cycle.
50: Pos. act. val. + limit value SLS4 / safety monitoring clock cycle.
51: Pos. act. val. - limit value SLS4 / safety monitoring clock cycle.
52: Standstill position + tolerance.
53: Standstill position - tolerance
54: Pos. act. val. + limit value nx / safety monit. clock cycle + tolerance.
55: Pos. act. val. + limit value nx / safety monit. clock cycle.
56: Pos. act. val. - limit value nx / safety monit. clock cycle.
57: Pos. act. val. - limit value nx / safety monit. clock cycle - tolerance.
58: Current stop request.
75: Velocity limit nx (p9546, p9346).
76: Stop response for SLS1 (p9563[0], p9363[0]).
77: Stop response for SLS2 (p9563[1], p9363[1]).
78: Stop response for SLS3 (p9563[2], p9363[2]).
79: Stop response for SLS4 (p9563[3], p9363[3]).
81: Velocity tolerance for SBR (p9548, p9348).
82: SGEs for SLS correction factor.
83: Acceptance test timer (p9558, p9358).
84: Trans. time STOP F (p9555, p9355).
85: Trans. time bus failure (p9580, p9380).
86: Ident. 1-encoder system.
87: Encoder assignment, 2nd channel (p9526, p9326).
89: Encoder limit freq.
230: Filter time constant for n < nx.
231: Hysteresis tolerance for n < nx.
232: Smoothed velocity actual value.
233: Smoothed velocity actual value + limit value nx / safety monitoring clock cycle + hysteresis toler-
ance.
234: Smoothed velocity actual value + limit value nx / safety monitoring clock cycle.
235: Smoothed velocity actual value - limit value nx / safety monitoring clock cycle.
236: Smoothed velocity actual value - limit value nx / safety monitoring clock cycle - hysteresis toler-
ance.
237: SGA n < nx.
1000: Watchdog timer has expired. Too many signal changes have occurred at safety-relevant inputs.
1001: Initialization error of watchdog timer.
1005: Pulses already suppressed for test stop selection.
1011: Acceptance test status between the monitoring channels differ.
1012: Plausibility violation of the actual value from the encoder.
1020: Cyc. communication failure between the monit. cycles.
1021: Cyc. communication failure between the monit. channel and Sensor Module.
1022: Sign-of-life for DQL Sensor Module CU
1032: Sign-of-life for DQL Sensor Module MM
1033: Error occurred during check of offset between POS1 and POS2 for DQL Sensor Module CU
1034: Error occurred during check of offset between POS1 and POS2 for DQL Sensor Module MM
5000 ... 5140: PROFIsafe message values.
5000, 5014, 5023, 5024, 5030 ... 5032, 5042, 5043, 5052, 5053, 5068, 5072, 5073, 5082 ... 5087,
5090, 5091, 5122 ... 5125, 5132 ... 5135, 5140: An internal software error has occurred (only for inter-
nal Siemens troubleshooting).
5012: Error when initializing the PROFIsafe driver.
5013: The result of the initialization is different for the two controllers.
5022: Error when evaluating the F parameters. The values of the transferred F parameters do not
match the expected values in the PROFIsafe driver.
5025: The result of the F parameterization is different for the two controllers.
5026: CRC error for the F parameters. The transferred CRC value of the F parameters does not match
the value calculated in the PST.
5065: A communications error was identified when receiving the PROFIsafe telegram.
5066: A time monitoring error (timeout) was identified when receiving the PROFIsafe telegram.
6000 ... 6166: PROFIsafe message values (PROFIsafe driver for PROFIBUS DP V1/V2 and PROFI-