Siemens Sinumerik 840D sl Diagnostic Manual page 505

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
61401
[Channel %1: ] Block %2: Probe does not switch, traversing path limited
by software limit position.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961, CYCLE971, CYCLE976, CYCLE977,
CYCLE978, CYCLE998
Remedy:
The position defined by a setpoint value cannot be reached as this would mean overrunning the soft-
ware limit position.
- Check specified setpoint value.
61402
[Channel %1: ] Block %2: Probe collision, traversing path limited by
software limit position
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE977
Remedy:
For the measuring variants Measure web/shaft, the position path in the plane was limited by the soft-
ware limit position. The probe switched in the following infeed along the infeed axis.
Check programmed position of software limit position.
61403
[Channel %1: ] Block %2: Work offset correction not executed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Call the SIEMENS hotline
61404
[Channel %1: ] Block %2: Tool correction not executed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check the dependent tool specifications.
61405
[Channel %1: ] Block %2: Tool environment does not exist
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Correct the name of the tool environment (_TENV) or create this environment.
61406
[Channel %1: ] Block %2: Check DL number
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
For 840D: Check parameter _DLNUM
For 840D sl: Check parameter DL
Check the number of the sum offset and that of the setup offset.
61407
[Channel %1: ] Block %2: Check 7th digit and higher of _KNUM
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check parameter _KNUM.
Check the the number of the sum offset and that of the setup offset.
61408
[Channel %1: ] Block %2: total offsets not present
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Set MD 18080, Bit 8=1
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-505

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents