Siemens Sinumerik 840D sl Diagnostic Manual page 479

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Reduce plane infeed.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61223
[Channel %1: ] Block %2: Approach path too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The approach path must not be less than zero.
Alarm triggered by following cycles: E_MI_CON, F_MI_CON.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Enter a greater value for the approach path.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61224
[Channel %1: ] Block %2: Retract path too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The retract path must not be less than zero.
Alarm triggered by following cycles: E_MI_CON, F_MI_CON.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Enter a greater value for the retract path.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61225
[Channel %1: ] Block %2: Swivel data record unknown
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An attempt was made to access a swivel data block which has not been defined.
Alarm triggered by following cycles: E_TCARR, F_TCARR.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select another swivel data block or define a new swivel data block.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61226
[Channel %1: ] Block %2: Inclinable head cannot be exchanged
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The parameter "Swivel data block" is set to "No". In spite of this, an attempt has been made to change
the swivel head.
Alarm triggered by following functions: E_TCARR, F_TCARR.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Set the parameter "Swivel data block" in the start-up screen "Rotary axes" to "Automatic" or "Manual".
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-479

Hide quick links:

Advertisement

Table of Contents
loading