Document Revision 3
___________________________________________________________________________________
___________________________________________________________________________________
6 - 156
8.5.2
Installation
Basic Port Package
A maximum of two CNF(8)-U( ) ETUs can be installed in slots
S1~S8.
The maximum number of CNF(8)-U( ) ETUs that can be installed
depends on other station cards installed. The system is limited by 64
trunk and station ports combined. This ETU shares the total number
of station ports in the system.
Calculating maximum capacity is based on the system having a
minimum of eight Electronic Station Interface (ESI) ports, four trunk
ports and a PKUII-U Unit installed.
Expanded Port Package
A maximum of two CNF(8)-U( ) ETUs can be installed in slots
S1~S8.
The maximum number of CNF(8)-U( ) ETUs that can be installed
depends on other station cards installed. The system is limited by
256 stations. This ETU shares the total number of station ports in the
system.
Calculating maximum capacity is based on the system having a
minimum of eight Electronic Station Interface (ESI) ports, four trunk
ports and a PKUII-U Unit installed.
8.5.3
Switch Settings
The CNF(8)-U( ) ETU has the following switches.
Reset Switch
Refer to
Conference Time Switch
Refer to
Time
Switch.
Party Size Switch
Table 6-53 CNF(8)-U( ) ETU Reset
Table 6-54 CNF(8)-U( ) ETU Maximum Conference
Table 6-53 CNF(8)-U( ) ETU Reset Switch
Switch
Setting
SW2
Press to Reset
Electra Elite IPK II
Switch.
Description
Host Reset Switch
Installing ETUs (Circuit Cards)