Switch Settings - NEC Electra Elite IPK II System Hardware Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 3
___________________________________________________________________________________
___________________________________________________________________________________
6 - 116
This ETU shares the total number of station ports in the system.
Each system can support only one CMS, CTI/VP, CTP, FMS, VMS,
or VMP ETU.
When installing this ETU, make all ETU DIP switch setting
changes before inserting it in the KSU. Ensure that KSU
is off.
7.4.3

Switch Settings

Refer to
Table 6-38 FMS(2)/(4)/(8)-U( ) ETU Switch
Revision Q26031 v 6.65 or lower. For Revision Q26031 v 6.68 or
higher, refer to
Functions.
Table 6-38 FMS(2)/(4)/(8)-U( ) ETU Switch Settings
Switch
1
2
3
4
Used for Revision Q26031 v 6.65 or lower.

Table 6-39 FMS(2)/(4)/(8)-U( ) ETU DIP Switch
Description
Normally Off.
(On to enable COM1.)
Normally Off.
When 1 and 2 are both On, COM1 is enabled for
HOSTKEY and the VM application is stopped for
Maintenance.
On to enable COM2 for remote RS-232/RJ-11.
Off to allow COM1 local connection.
Not Used.
Electra Elite IPK II
Settings, for