Wall Mounting The Pgd(2)-U10 Adp (Optional) - NEC Electra Elite IPK II System Hardware Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 3
___________________________________________________________________________________
6.4
___________________________________________________________________________________
7 - 10
Figure 7-9 PGD(2)-U10 ADP Connections
9.
Install a modular jack for each PGD(2)-U10 ADP. For each module, run
one-pair 24 AWG station cable from the crossconnect block to a modular
jack. Ground the unused pair.
10. Terminate the extension leads to GRN/RED of the modular jack.
Terminate the unused leads to the jack.
11.
Install bridging clips as required.
For the module to ID correctly, set the circuit type to 0 for the port in
Program 10-03-01 prior to connecting the line cord.
12. Plug a modular line cord from the mod jack to the CN1 connector on the
PGD(2)-U10 ADP.

Wall Mounting the PGD(2)-U10 ADP (Optional)

1.
To wall mount the PGD(2)-U10 ADP, insert two wood screws 100mm
apart (3 15/16"). Leave 3mm (1/8") of the screw exposed. The screws
can be installed either vertical or horizontal, depending on which position
fits best for your location.
Installing Electra Elite IPK II KSU Common Optional Equipment
CN3
Channel 2
CN3
Channel 1
(to ESIU port)
Electra Elite IPK II
CN1
RCA
Plugs