Figure 11-28 Attaching The Hf-R Unit To The Multiline Terminal; Installing An Hf-R Unit On Any Dtr/Dth Multiline Terminal (Except Dtr-2Dt-1) - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
System Hardware Manual
4.1.1
Installing an HF-R Unit on any DTR/DTH Multiline Terminal (except
DTR-2DT-1)
1.
With the terminal upside down, facing from the bottom of the
open cover, install this unit in terminal adapter Slot 1.

Figure 11-28 Attaching the HF-R Unit to the Multiline Terminal

2.
Plug the tabs marked A and B into adapter slots, then snap the
tab on the other end of the adapter into the receptacle marked
C. Refer to
Multiline
3.
Replace the base plate (or wall mount unit) and attach the line
cord. Refer to
System on page
Figure 11-28 Attaching the HF-R Unit to the
Terminal.
Section 3 Connecting a Multiline Terminal to the
10-12.
Issue 2.0
11 - 27