Table 9-3 Ada-L Unit Switch Settings - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 2.0
9 - 72
To provide control to the recorder or to enable/disable the record start warning
tones, refer to
Table 9-3 ADA-L UNIT Switch
Switch
Dip
Switches
(DSW)
Do not connect T1 and T2 when DSW switches 3 and 4 are On.
Figure 9-48 ADA-L UNIT

Table 9-3 ADA-L UNIT Switch Settings

Record Confirmation Tone
DSW 1
On = Tone On (Default)
Off = Tone Off
Connection for the Record Confirmation Tone
DSW 2
Source
and
On = Connect
DSW 3
Off = No Connection (Default)
Output the Hook Signal to External Recording
Device (Requires cable from T1/T2)
DSW 4
On = Output (Default)
Off = No Output
Termination Impedance for OUT Jack
On = 30ohms (Recording level is lower)
DSW 5
Off = 600ohms (Recording level is higher)
(Default = Off)
Upgrade F/W Version (Not normally used)
DSW 6
On = (Default)
DSW 7
Not Used
and
Off = (Default)
DSW 8
Installing SV8100 Optional Equipment
UNIVERGE SV8100
Settings.
Description/Settings