UNIVERGE SV8100
Level:
IN
Description
(This program is aviable for V7000 or higher)
Use Program 20-46 : Security Sensor Setup to set system Security Sensor options.
Input Data
Item
Programming Manual
Program 20 : System Option Setup
Security Sensor Number
No.
01
Sensor Mode
02
Internal Paging Group for Warning Message
03
External Paging Group for Warning Message
04
VRS Message for Warning
05
Auto Dial Number Area Setting
06
VRS Message for Answer
07
Auto Dial Wait Timer
08
Time of Repeat Auto Dial
09
Auto Dial Call TIme
10
Monitored Terminal
11
Interval of Auto Dial
20-46 : Security Sensor Setup
Item
1~6
Input Data
0 = Off
1 = On
0 = No Internal Paging
1 ~ 64 Paging Group
0 = No External Paging
1 ~ 8 (Paging Group)
0 = Warning Tone
1~100 (VRS Warning
No.)
0~1999
0 = Warning Tone
1~100 (VRS Warning
No.)
0 = Report Immediately
1~64800 (sec)
0 = No Repeat
1~255 (times)
0 = No Report
1~3600 (sec)
Extension Number (Up to
8 digits)
0 ~ 3600
Issue 10.1
Default
0
0
0
0
1999
0
10
3
120
No Setting
0
2 - 301