10-21: Cd-Cp00 Hardware Setup - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Program 10 : System Configuration Setup
Level:
IN
Description
Use Program 10-21: CD-CP00 Hardware Setup to set up External MOH and
General Purpose Relay on the CD-CP00 blade.
Input Data
Item
Item
No.
04
External Source I/O
Selection on CD-CP00
Determines the external music
source input/output selection for
CD-CP00 CN8 and CN9.
05
General Purpose Relay
Switch Selection on
CD-CP00
06
Drive Timer Setup
Feature Cross Reference
None
2 - 40
0
= External MOH (CN8)/ External
Speaker(CN9)
1
= BGM source (CN8)/ External
Speaker(CN9)
2
= External MOH (CN8)/BGM source
(CN9)
Relationships between CN number and
Relay number are as follows:
CN8 = Relay2
CN9 = Relay1
0
= Off
1
= Relay 1 on CD-CP00
2
= Relay 2 on CD-CP00
0~64800
0 = No Setting
1 = 0.1s
2 = 0.2s
3 = 0.3s
:
10 = 1.0s
Conditions
None

10-21: CD-CP00 Hardware Setup

Input Data
Program 10 : System Configuration Setup
UNIVERGE SV8100
Related
Default
Program
0
0
0
10-21-05