NEC Univerge SV8100 Programming Manual page 907

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Alarm
Type
Report
No.
13
0
Charge
0
Management
Link Error
14
0
LAN Link
0
Error
15
0
Network Keep
0
Alive Error
17
0
Denial of
1
service
29
0
Charge
0
Management
Buffer full
30
0
SMDR Buffer
2
full
31
0
Auto Dial after
1
Sensor
Detection
32
0
Remote
1
watch
function
performs auto
dial
33
0
fall to auto
1
dial by
security
function
Programming Manual
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
The link with the charge
management device came
off.
The link with LAN on
CD-CP00 came off.
1. The network connection
has been cut.
2. Network Keep Alive
restoration.
3. Response notification on
network Keep Alive.
The system received illegal
packet.
The temporary buffer for
the charge management in
main device overflowed,
and a part of unoutput
charge data disappeared
because it could not output
the charge management
data.
The temporary buffer for
SMDR in main device
overflowed, and a part of
unoutput SMDR data
disappeared because it
could not output SMDR
data.
Auto dialing occurs after
sensor detection.
Remote watch funvtion
performs auto dial
Fall to auto dial by security
function.
Cause
Action
1. Wiring problem
1. Confirmed that there
in connecting main
is no problem in wiring
device with charge
to connect a main
management
device with the charge
device.
management device.
2. PC Problem.
(Whether ping passes
for LAN connection is
confirmed.)
2. Restart the charge
management software.
3. Reboot PC, and start
charge management
software.
1. LAN cable
Confirm the operation
defective.
of LAN connector, LAN
2. Connected HUB
cable, and HUB again.
broken.
3. Defective
CD-CP00
1. LAN cable is
1. Confirm that the
defective.
defect is on the Network
2.Net side trouble.
side.
3. Packet block by
2. Confirm the settings
firewall.
of HUB and the router,
4. Repetition of IP
etc.
address.
Service outage
Confirm whether to find
(Dos attack)
abnormality on the net
side.l
1. The charge data
1. Please print and
is printed and not
delete the charge data
deleted at the
at the simple charge
simple charge
management.
management.
2. Please connect the
2. The charge data
charge management
is not output to PC
software for the charge
for the charge
management software
management
and output the charge
software.
data.
1. Problem of
1. Confirm whether
wiring to connect
there is problem in
main device with
wiring to connect a
PC.
main device with PC.
2. PC Problem.
2. Execute the
reactivation of PC.
Sensor detect an
No action needed.
abnormality and
makes an
emergency call.
No action needed.
All auto dial trunks
No action needed.
are busy.
Issue 10.1
Alarm
Recovery
Status
When the
ERR
connection
REC
returns
normally, the
error is
recovered.
When the
ERR
connection
REC
returns
normally, the
error is
recovered.
When the
ERR
connection
REC
returns
WAR
normally, the
error is
recovered.
WAR
When the
ERR
output is
REC
restarted, the
error is
recovered.
However, the
charge
management
data after the
error occurs is
not recorded.
When the
ERR
output is
REC
restarted, the
error is
recovered.
However, the
SMDR data
after the error
occurs is not
recorded.
2 - 871