80-11: Mfc Tone Receiver Setup (Ot) - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Program 80 : Basic Hardware Setup for System
Level:
MF
Description
Use Program 80-11: MFC Tone Receiver Setup to various data for the MFC signal
detection.
Input Data
Input Data
Item No.
2 - 692

80-11: MFC Tone Receiver Setup (OT)

MFC Tone Receiver Type Number
Item
01
Detect Level
02
Start delay time
03
Min. detect level
1 = MFC Receiver for Extension
2 = MFC Receiver for Trunk
3 = Reserved
4 = Reserved
5 = Reserved
Input Data
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
0~255 (0.25step, 0ms~64ms)
0~15
MFC Tone 0: -10dBm(0) to -25dBm(15)
MFC Tone 1: -15dBm(0) to -30dBm(15)
MFC Tone 2: -20dBm(0) to -35dBm(15)
MFC Tone 3: -25dBm(0) to -40dBm(15)
MFC Tone4: -30dBm(0) to -45dBm(15)
MFC Tone 5: -35dBm(0) to -50dBm(15)
MFC Tone 6: -40dBm(0) to -55dBm(15)
Program 80 : Basic Hardware Setup for System