82-11: Lca Initial Data Setup (Au) - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Program 82 : Basic Hardware Setup for Extension
Level:
IN
Description
Use Program 82-11: LCA Initial Data Setup to define the various timers for LCA
Packages.
Input Data
Ite
m
No
.
01
02
03
Feature Cross Reference
None
2 - 752
Item
Specify a time for detection
Bounce Protect
Time
of a valid off-Hook indication
that is long enough to
prevent an unintentional
bounce of the receiver from
being detected as a new Off-
Hook indication from a Single
Line Telephone.
Specify the minimum
HookFlash Start
Time
hookflash time from a Single
Line Telephone or analog
Voice Mail system before it is
detected as the beginning of
a valid hookflash.
Specify the maximum
HookFlash End
Time
hookflash duration from a
Single Line Telephone to
receive a second dial tone.
Conditions
None

82-11: LCA Initial Data Setup (AU)

Description
0 = No Setting
1~15 = 100ms~1.5sec
0 = 40ms
1~15 = 90ms~790ms
0 = HST+0ms
1~15 =
HST+100ms~HST+1500
ms (HST=Hookflash
Start Time)
Program 82 : Basic Hardware Setup for Extension
UNIVERGE SV8100
Input
Default
3 (300ms)
0 (40ms)
1 (1600ms)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents