Toll Restriction Class - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Level:
IN
Description
Use Program 21-05: Toll Restriction Class to set the system Toll Restriction classes
(1~15).
Input Data
Item
No.
01
International Call
Restriction Table
02
International Call
Permit Code Table
04
Maximum Number
of Digits Table
Assignment
05
Common Permit
Code Table
06
Common
Restriction Table
2 - 316
Program 21 : Outgoing Call Setup
Toll Restriction Class Number
Item
Input Data
0 =Unassigned
(No)
1 = Assigned
(Yes)
0 =Unassigned
(No)
1 = Assigned
(Yes)
1~4 = Table
0 = Disable
(None)
0 =Unassigned
(No)
1 = Assigned
(Yes)
0 =Unassigned
(No)
1 = Assigned
(Yes)

21-05 : Toll Restriction Class

Default
Description
1, 6~15 = 0
This option assigns/
2~5 = 1
unassigns the International
Call Restrict Table for the
Toll Restriction Class you
are programming. Enter
International Call Restrict
Table data in Program 21-
06-01.
1, 3~15 = 0
This option assigns/
2 = 1
unassigns the International
Call Permit Table for the Toll
Restriction Class you are
programming. Enter
International Call Permit
Table data in Program 21-
06-02.
1, 2, 6~15 =
Select the table (defined in
0
21-06-03) to be used to
3 = 1
determine the maximum
4 = 2
number of digits allowed for
5 = 3
outgoing calls.
1, 8~15 = 0
It chooses whether the table
set up by 21-06-04 is
2~7 = 1
referred to, or not referred
to.
1, 6~15 = 0
It chooses whether the table
set up by 21-06-05 is
2~5 = 1
referred to, or not referred
to.
Program 21 : Outgoing Call Setup
UNIVERGE SV8100
1~15
Related
PRG
21-06-01
21-06-02
21-06-03
21-06-04
21-06-05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents