51-17:NetLink DT700 Server Individual Information Setting

Level:
IN
Description
Use Program 51-17: NetLink DT700 Server individual Information Setting to set
the information of DT700 Server on each system in NetLink.
.
Input Data
Input Data
Feature Cross Reference
None
Programming Manual
System ID
Item
No.
01
Register Port
02
Subscribe Session Port
Conditions
Make sure TCP/UDP port doesn't interfere with other IP Terminal. Exception with
10-46-06, 10-46-13.
If 10-46-14 is ON make sure it wont have a same IP Address in the same
Network.
When the 51-01-01 is 0 this program will be ignored. Instead it will use 10-46-13.
Program 51 : NetLink Service
1 -50
Item
Input Data
0~65535
0~65535
Issue 10.1
Default
5080
5081