NEC Univerge SV8100 Programming Manual page 908

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Alarm
Type
Report
No.
35
0
CS Blocking
0
36
0
CS error
0
notification 1
37
0
CS
0
transmission
error.
38
0
CSIU Dch
0
Error×
39
0
CSIU trans-
0
mission error.
2 - 872
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
The link of the CSIU and
CS came off.
CS detected the problem
occurring in the air
synchronous signal
between CS-CSIU, BBIC
reset was executed, and it
was restored automatically.
Because CS had not
returned the response to
the control signal from a
main device longer than
the fixed time, it was
restored automatically
specifying reset to
concerned CS with a main
device.
It was restored
automatically specifying
reset to concerned CS with
a main device because a
main device had detected
the control signal from a
main device not normally
reaching CS.
This alarm is integrated
into Communication fault
between the CD-CP00 and
other PKG, and it is not
used in SV8100.
Cause
Action
1. Outgoing noise.
Confirm the following
2. Method of setting
when it happens
up CS.
frequently during
3. Wiring to
operation.
connect CSIU unit
1. Please confirm CS is
with CS.
normally connected.
4. Hard defect of
2. Please confirm the
CS.
wiring between
5. Hard defect of
CSIU-CS is normal.
CSIU.
3. Please exchange
CS.
4. Please exchange
CSIU.
1. Outgoing noise.
Confirm the following
2. Method of setting
when it happens
up CS.
frequently during
3. Wiring to
operation.
connect CSIU unit
1. Please confirm CS is
with CS.
normally connected.
4. Hard defect of
2. Please confirm the
CS.
wiring between
5. Hard defect of
CSIU-CS is normal.
CSIU.
3. Please exchange
CS.
4. Please exchange
CSIU.
1. Outgoing noise.
Confirm the following
2. Method of setting
when it happens
up CS.
frequently during
3. Wiring to
operation.
connect CSIU unit
1. Please confirm CS is
with CS.
normally connected.
4. Hard defect of
2. Please confirm the
CS.
wiring between
5. Hard defect of
CSIU-CS is normal.
CSIU.
3. Please exchange
CS.
4. Please exchange
CSIU.
1. Outgoing noise.
Confirm the following
2. Method of setting
when it happens
up CS.
frequently during
3. Wiring to
operation.
connect CSIU unit
1. Please confirm CS is
with CS.
normally connected.
4. Hard defect of
2. Please confirm the
CS.
wiring between
5. Hard defect of
CSIU-CS is normal.
CSIU.
3. Please exchange
CS.
4. Please exchange
CSIU.
Program 90 : Maintenance Program
UNIVERGE SV8100
Alarm
Recovery
Status
The error is
ERR
recovered
REC
when
reconnecting
or exchanging
it.
This error has
ERR
been
REC
recovered
when it is
notified.
This error has
ERR
been
REC
recovered
when it is
notified.
This error has
ERR
been
REC
recovered
when it is
notified.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents