NEC Univerge SV8100 Programming Manual page 912

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Alarm
Type
Report
No.
86
0
Data base
2
replication
fail.
87
0
Data base
2
replication
fail.
88
0
NetLink
2
phase shift.
89
0
NetLink
2
phase shift.
90
0
NetLink
2
phase shift.
91
0
Primary auto-
2
integration.
92
0
Primary
2
compulsion
specification.
93
0
NetLink node
2
connection
detection.
94
0
NetLink node
2
secession
detection.
95
0
Data Base
2
replication
failure.
96
0
Data base
1
recovery fail.
97
0
DB recovery
2
operation
start.
98
0
DB recovery
2
operation
finish.
99
0
NetLink
1
Configuration
Error
2 - 876
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
Because the versions of
DB is different, replication
cannot be executed
between Primary and
Secondary.
Because the error occurred
in the communication
between Primary and
Secondary, replication
cannot be executed.
Operation began as
Primary.
Operation began as
Secondary.
It shifted to the node
search mode.
Primary auto-integration
function operated.
The Primary compulsion
specification function was
executed.
Node connection with
NetLink Primary was
detected.
Secession of the node
detected with NetKink
Primary.
Because Secondary is in
programming mode, the
replication of DB cannot be
executed.
Error happened when
DataBase recovery
operation.
Backup/Restore
Start Data base recovery
operation.
Backup/Restore/Delete
Finish DataBase recovery
operation.
Backup/Restore/Delete
This alarm occurs when
the system tries to start as
NetLink without MEMDB
Cause
Action
The versions of
1. Confirm the version
data bases
of data bases of
between Primary
Primary and Secondary
and Secondary is
using PC PRO.
different.
2. Check with maker on
uncertain points.
LAN link between
Confirm LAN link
Primary and
between Primary and
Secondary was
Secondary.
disconnected.
Operation began as
No action is necessary.
Primary.
Operation began as
No action is necessary.
Secondary.
Shifted to the node
No action is necessary.
search mode.
Primary auto-
No action is necessary.
integration function
operated.
Primary
No action is necessary.
compulsion
specification
function was
executed.
Node connection
No action is necessary.
with NetLink
Primary was
detected.
Secession of the
No action is necessary.
node detected with
NetKink Primary.
Logging in with
Log out from secondary
Secondary in the
programming mode.
Web Pro or the PC
Pro is possibility
the cause.
Lack of resource
Delete unnecessary file
Memory, protected
and restore open area,
area, recovery data
then try operation
file corruption are
again.
possible reason for
this.
Start Data base
No action is necessary.
recovery operation.
Finish Data base
No action is necessary.
recovery operation.
PRG51-01-01 is set
Install PZ-ME50 when
without PZ-ME50.
NetLink is enable.
Program 90 : Maintenance Program
UNIVERGE SV8100
Alarm
Recovery
Status
WAR
WAR
INF
INF
INF
INF
INF
INF
INF
WAR
WAR
INF
INF
WAR