Description
Use Program 51-02: NetLink System Individual Setting to set system data for each
NetLink system.
Input Data
Item
No.
01
02
03
04
Programming Manual
Program 51 : NetLink Service

51-02 : NetLink System Individual Setting

System ID
Item
System Name
This is the name given to each system.
Time Zone (Hour)
Determines the time offset from the Primary
system.
(0 = -12, 1 = -11, 2 = -10.... 12 = 0
13 = +1, 14 = +2, 24 = +12)
This setting affects Time Display on MLT
(see 51-13-02).
Time Zone (Minute)
Determines the time offset from the Primary
system.
(0 = -60, 1 = -59, 2 = -58.... 120 = +60)
This setting affects Time Display on MLT
(see 51-13-02).
Authenticate System MAC Address
To use this function, set PRG 51-13-03 to 1
(enable), NetLink systems will reject the
connection from unauthenticated system
access.
1~50
Input Data
Up to 20 characters.
0~24 (-12 ~ +12
hours)
0~120 (-60 ~ +60)
00-00-00-00-00-00~
FF-FF-FF-FF-FF-FF
Issue 10.1
Default
blank
12
60
00-00-00-00-00-00