Program 80 : Basic Hardware Setup for System
Level:
IN
Description
Use Program 80-08: MFC Tone Setup to define the duration (On time) and pause
(Off time) for MFC dialing. This option affects all trunk line calls system wide. And
also it is possible to adjust the level of tone.
Input Data
Item No.
Pause
Feature Cross Reference
None
2 - 688
Item
01
Duration (On time)
02
Pause (Off time)
03
Tone Level
Duration
Conditions
None

80-08: MFC Tone Setup (OT)

Input Data
1~255
(20ms ~ 5100ms)
1~255
(20ms ~ 5100ms)
1~97
(-45dB ~ +3dB)
Program 80 : Basic Hardware Setup for System
UNIVERGE SV8100
Default
5 (100ms)
5 (100ms)
77 (-7dB)