NEC Univerge SV8100 Programming Manual page 911

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Alarm
Type
Report
No.
66
0
SIP extension
2
License Error.
67
0
SIP illegal
0
Packet
received
68
0
VoIP DSP All
2
Busy Alarm
71
0
CID Buffer
2
Threshold
80
0
NetLink start
1
error.
81
0
NetLink call
2
trouble
information.
82
0
NetLink
2
Virtual Slot
accommod.
error.
83
0
NetLink
2
Communicati
on Error.
84
0
NetLink
2
License Error
85
0
NetLink node
2
connection
refusal.
Programming Manual
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
More than the number of
licenses to which the SIP
extension terminal was
turned on at REGISTER.
The system received illegal
packet.
1. Provides alert when all
DSP resources are being
used.
2. Used to troubleshoot or
alerting when upgrade is
needed.
When the number of CID
records is over the limit,
CID buffer threshold alarm
(71) can be reported.
The error occurred when
NetLink started.
1. The trouble occurred by
the NetLink relation.
2. The DSP resource was
not acquired at incoming/
outgoing.
The trouble occurred with
virtual Slot relation.
• It exceeded the upper slot
accommodation.
• It failed to make a virtual
slot.
1. Communication error
occurred on NetLink.
2. Checksum error
occurred.
3. Index error occurred.
1. License error occurred
on NetLink.
2. Expiration date of the
license approaches.
3. License nullified.
The connection of
Secondary was refused in
NetLink.
• SystemID overlaps.
• SystemID is illegal.
• The license is insufficient.
• Memory shortage.
Cause
Action
• Wrong number of
1. Confirm the number
licenses.
of licenses for SIP
extension terminals.
2. Check with maker on
uncertain points.
A client or network
Check with maker on
was illegal state.
uncertain point, when
happening frequently
when operating it.
Not enough DSP
Install PZ-VMDB with
resources in
more DSP resources.
system.
•Defect on
There is a defective
CD-CP00.
possibility of hardware.
Please inquire of the
maker.
PZ-32IPLA DSP
1. Confirm wiring and
not acquired.
the system data setting.
2. Check with maker on
uncertain points.
Exceeds slot
1. Confirm upper slot
accommodation in
number.
the NetLink system.
2. Check with maker on
uncertain points.
1. The Router
1. Confirm LAN
setting is wrong.
connector and wiring.
2. LAN Link error.
2. Check with maker on
uncertain points.
• Net side error.
1. Approaching
1. Confirm license
expiration date of a
information.
temporary license.
2. A temporary
2. Check with maker on
license was
uncertain points.
nullified.
1. SystemID
1. Confirm the setting
Repeated.
and license information
2. SystemID is
on SystemID.
illegal.
3. The number of
2. Check with maker on
licenses is wrong.
uncertain points.
• Insufficient
system memory.
Issue 10.1
Alarm
Recovery
Status
When the
WAR
number of
registration of
SIP extension
terminals falls
below the
number of
licenses.
INF
ERR
WAR
WAR
WAR
WAR
WAR
2 - 875

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents