(2) Starting from the special function switch
To start the sequence program monitor (Ladder), touch a special function switch that has the following settings:
[Sequence Program Monitor (Ladder)] is selected for [Switch Action], and [Use One-touch Ladder Jump] is selected.
To start the sequence program monitor (R ladder), touch a special function switch that has the following settings:
[Sequence Program Monitor (R ladder)] is selected for [Switch Action], and [Use One-touch Ladder Jump] is
selected.
Operation at start differs depending on the setting contents of the special function switch.
For the setting items for the special function switch, refer to the following.
(○: Set, ×: Not set)
Search Method
Specify Search Device
Specify Connected Station
*1
*2
(a)
Operations for searching a device with specifying the file name
Starting the sequence
program monitor
(Ladder) or the
sequence program
monitor (R ladder)
(b)
Operations for searching a device without specifying the file name
Starting the sequence
program monitor
(Ladder) or the
sequence program
monitor (R ladder)
(c)
Operations for searching a connected station with specifying the file name
Starting the sequence
program monitor
(Ladder) or the
sequence program
monitor (R ladder)
(d)
Operations for setting a connected station without specifying the file name
Starting the sequence
program monitor
(Ladder) or the
sequence program
monitor (R ladder)
4 - 12
4.3 Display Operation
GT Designer3 (GOT2000) Screen Design Manual
Setting
*1
*2
When [Specify Search Device] is selected, set [Ladder Search Device] and [Ladder Search Mode].
The setting of PLC station number is included in the [Ladder Search Device] setting.
When [Specify Connected Station] is selected, set [CH No.] and [Network].
If [Other] in [Network] is selected, also set [Net No.], [Station No.] and [CPU Machine].
Automatic PLC read
(The set sequence
program file)
Automatic PLC read
(All sequence
program files)
Automatic PLC read
(The set sequence
program file)
PLC read screen
POINT
POINT
POINT
Operations for the special function switch when not using the One-touch Ladder Jump
function
When the [Use One-touch Ladder Jump] is not selected, the operation for touching the special
function switch is the same as when starting from the utility.
4.3 Display Operation
Specify Search File
×
×
Automatic search for
Ladder Search
Device
(Coil/Factor)
Automatic search for
Ladder Search
Device
(Coil/Factor)
Ladder monitor
screen
Operation for touching the special
function switch
(a)
(b)
(c)
(d)
Ladder monitor
screen
(The search result is
displayed.)
Ladder monitor
screen
(The search result is
displayed.)

Advertisement