(2) Inverter and servo amplifier
The backup/restoration is usable for an inverter or servo amplifier that is connected to the GOT through an RCPU
(master station). The inverter or servo amplifier must be connected to the RCPU on the CC-Link IE Field Network.
The RCPU must be connected to the GOT by Ethernet.
Inverter
Target controller
FREQROL-A series
MELSERVO-J4 series
*1
Use a module with version 09 or later.
*2
Use a module with version 02 or later.
*3
Use a module having version 09 or later of the network part.
■3. Required hardware
The backup / restore, data storage is required.
■4. Required system application (extended function)
For the system application (extended function) required, refer to the following.
1.2 System Applications (Extended Functions) Required for Each Function
(1) System application (extended function)
Write the package data that contains the system application (extended function) for the backup/restoration to the
GOT.
For the communication method with the GOT, refer to the following.
GT Designer3 (GOT2000) Screen Design Manual
(2) System application (extended function) size
To install a system application (extended function) to the GOT, enough space in the user area is required.
For information on how to check the available space of the user area and each data size, refer to the following.
GT Designer3 (GOT2000) Screen Design Manual
■5. Required software to be installed
To restore the C language module backed up from the CNC C70, Remote Monitor Tool is required.
(1) How to obtain the software
Contact your local distributor.
(2) Operating environment
For the operating environment of the software, refer to the following.
MITSUBISHI CNC C70 / C64 Series Remote monitor tool Operating Manual
(3) How to install
For the installation instructions, refer to the following.
MITSUBISHI CNC C70 / C64 Series Remote monitor tool Operating Manual
Servo
Amplifier
CC-Link IE Field Network connection
Intelligent function module
*1
*1
RJ71GF11-T2
, RJ71EN71
*2
*2
RD77GF4
, RD77GF8
, RD77GF16
-
(Ethernet port built in the PLC CPU)
*1
*1
RJ71GF11-T2
, RJ71EN71
*2
*2
RD77GF4
, RD77GF8
, RD77GF16
-
(Ethernet port built in the PLC CPU)
RCPU
(master station)
Ethernet connection
R04CPU, R08CPU, R16CPU, R32CPU,
R120CPU
*2
*3
R04ENCPU
, R08ENCPU
*3
R32ENCPU
, R120ENCPU
R04CPU, R08CPU, R16CPU, R32CPU,
R120CPU
*2
*3
R04ENCPU
, R08ENCPU
*3
R32ENCPU
, R120ENCPU
10.2 Specifications