Mitsubishi Electric GOT2000 Series User Manual page 87

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

Item
Display format
7) Message display
Displays error messages.
8) [Register] key
Registers devices.
Displays the device entry window when touched.
3.3.5 ■2. Window for entering the device
9) [Test] key
Carries out a test operation.
3.3.8 Test operation for the monitor device ([Test])
10) [Layput] key
Changes the display of items.
The display of the following items can be changed.
• Number of the columns of the devices to be displayed
• Comments (can be switched between displaying and hiding)
3.3.9 Switching the display (number or columns, comment display) ([Layout])
11) [Connect] key
Switches the monitor target for the device monitor.
Touch the key to display the communication setting dialog.
3.3.4 ■2. Communication setting dialog
Represents the display format of the device value.
The character on the left represents the data range of the device.
• [W]: Word (16 bits)
• [D]: Double-word (32 bits)
• [L]: 64 bits
The character string on the right represents the display format of the device value.
• [K±]: Signed decimal
• [K+]: Unsigned decimal
• [HEX]: Hexadecimal
• [BIN]: Binary
• [EXP]: Exponential notation
• [FIT]: Decimal representation
The display format can be changed when touched.
3.7 BM Monitor (Monitoring Buffer Memory)
Description