Siemens SINUMERIK 840D Diagnostics Manual page 172

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
12728
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12730
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12740
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14000
Parameters:
Definitions:
Reactions:
1-172
For plane selection with G17, G18, G19 either program the basic axis of the coordinate
system or the assigned parallel axis.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 distance for double turret not set
%1 = Channel number
%2 = Block number, label
The tool clearance for the double turret head in the setting data
$SC_EXTERN_DOUBLE_TURRET_DIST is 0.
- Correction block
- Interface signals are set.
- Alarm display.
Enter tool clearance for the double turret head in the setting data
$SC_EXTERN_DOUBLE_TURRET_DIST.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no valid transformation machine data parameterized
%1 = Channel number
%2 = Block number, label
The machine data $MC__TRAFO_TYPE_1, $MC_TRAFO_AXES_IN_1[1],
$MC_TRAFO_AXES_IN_2[1] are incorrectly set for G07.1, G12.1.
- Correction block
- Interface signals are set.
- Alarm display.
Enter valid transformation identifier for TRACYL in $MC__TRAFO_TYPE_1 and the
rotary axis number in $MC_TRAFO_AXES_IN_1[1] or $MC_TRAFO_AXES_IN_2[1].
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 modal macro call %3 not possible
%1 = Channel number
%2 = Block number, label
%3 = Source string
When calling a modal macro no other modal macro, modal cycle or modal subroutine may
be active.
- Correction block
- Interface signals are set.
- Alarm display.
Modify part program
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 illegal end of file
%1 = Channel number
%2 = Block number, label
Part program was not terminated with M30, M02 or M17. This error is also signalled at the
host if the environment variables NCPROG or NCUPROG have been set to a non-existing
file.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.