10.04
Remedy:
Program Continuation:
15150
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15160
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15165
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Please inform the authorized personnel/service department. No remedial measures are
available for the further execution of the current NC program, however:
1. Reduce log file size requirement by:
Reducing the distance between the preprocessing and the main run via appropriate pre-
processing stops
STOPRE.
2. The logfile should be increased in size by means of the channel-specific data:
Modify MD 28000: MM_REORG_LOG_FILE_MEM and
Modify MD 28010: MM_REORG_LUD_MODULES
Attention!
A change in these machine data also causes a reallocation of the NCK user memory and
the standard machine data are then loaded. Unless a data save is performed, there will be
a LOSS OF DATA!
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 block %2 reload from external aborted
%1 = Channel number
%2 = Block number, label
Execution from external was aborted because the reload buffer does not have enough
machine function blocks (traversing blocks, auxiliary function, dwell time etc.). Back-
ground: When already executed machine function blocks are released, memory becomes
available in the reload buffer. If machine function blocks are no longer released, nothing
can be reloaded - this results in a deadlock situation.
Example: Definition of extremely long curve tables via execution from external.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Insert machine function blocks in the part progam.
• Increase the size of the reload buffer ($MN_MM_EXT_PROG_BUFFER_SIZE).
• Decrease the size of the curve table (Note: Blocks within CTADDEF/CTABEND are not
machine function blocks).
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 wrong preprocessing configuration
%1 = Channel number
%2 = Block number, label
A block element is required, but the block element memory is empty.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Modify the block search con-
figuration in machine data 28060 MM_IPO_BUFFER_SIZE (decrease size of IPO buffer if
necessary) or 28070 MM_NUM_BLOCKS_IN_PREP.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 error when translating or interpreting Asup %3
%1 = Channel number
%2 = Block number, label
%3 = String