Siemens SINUMERIK 840D Diagnostics Manual page 539

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
300009
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300010
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Configure MD 30230
ENC_INPUT_NR [e] according to the encoder connector used or plug the encoder cable
onto the other connector.
If the encoder used corresponds to the input in the MD, there is a hardware fault on the
drive module. Replace the module!
Switch control OFF - ON.
Axis %1 drive %2 measuring circuit %3 wrong measuring circuit type (type %4
used)
%1 = NC axis number
%2 = Drive number
%3 = Measuring circuit number
%4 = Measuring circuit type
The available, displayed actual value module on the drive FBG cannot process the signal
type that was stated via the axis-specific machine data 30240 ENC_TYPE [e]=S (e ...
encoder index - the position control works with this encoder, E ... , S ... signal type of the
actual value encoder - 0 ... simulation axis without hardware, 1 ... raw encoder signals, 2
... rectangle signals).
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
Set MD 30240 ENC_TYPE [e] to 1 (0 should only be entered for pure simulation axes
which are to travel in the actual-value display only).
Switch control OFF - ON.
Axis %1 drive %2 active without NC axis assignment
%1 = NC axis number
%2 = Drive number
A drive is active that is not used/addressed by any NC axis (actual value, setpoint).
All active drives must be assigned to an axis with respect to the setpoint value or the
actual value.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.