10.04
Reactions:
Remedy:
Program Continuation:
15700
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15800
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15810
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Program the angle of shear in accordance with the geometrical conditions of the machine
and workpiece system.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 illegal cycle alarm number %3
%1 = Channel number
%2 = Block number, label
%3 = Cycle alarm number
A SETAL command has been programmed with a cycle alarm number less than 60 000 or
greater than 67 999.
Alarm reactions of Siemens standard cycles:
Nos. 61,000 -61,999: Interpreter stop; delete with Reset
Nos. 62 000 - 62 999: Compensation block; delete with NC Start
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Program alarm number in the SETAL instruction in the correct range.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 wrong starting conditions for CONTPRON/CONTDCON
%1 = Channel number
%2 = Block number, label
There is an error in the start conditions for CONTPRON/CONDCON:
• G40 not active
• SPLINE or POLY active
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 wrong array dimension for CONTPRON/CONTDCON
%1 = Channel number
%2 = Block number, label
The number of columns for the array created for CONTPRON/CONTDCON does not con-
form to the current programming guide.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with the RESET key. Restart part program.