10.04
Remedy:
Program Continuation:
14402
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14403
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14404
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Please inform the authorized personnel/service department.
• Modify part program; program defined transformations only.
• Check MD 24100 TRAFO_TYPE_n (assigns the transformation to part program instruc-
tions).
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 spline active at transformation change
%1 = Channel number
%2 = Block number, label
A change of transformation is not allowed in a spline curve section. A series of spline
blocks must be concluded.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 preprocessing and main run might not be synchronized
%1 = Channel number
%2 = Block number, label
Positioning axis runs cannot be accurately calculated beforehand. Consequently, the
position in the MCS is not known exactly. It might therefore be possible that a change in
the multiple significance of the transformation has been performed in the main run
although no provision was made for this in the preprocessing run.
- Alarm display.
Modify part program. Synchronize preprocessing run and main run.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 illegal parameterization of transformation
%1 = Channel number
%2 = Block number, label
Error has occurred when selecting transformation.
Possible causes of error:
• An axis traversed by the transformation has not been enabled:
• is being used by another channel (-> enable)
• is in spindle mode (-> enable with SPOS)
• is in POSA mode (-> enable with WAITP)
• is concurrent Pos axis (-> enable with WAITP)
• Parameterization via machine data has an error
• Axis or geometry axis assignment to the transformation has an error,
• Machine data has an error (-> modify machine data, restart)
Please note: Any axes not enabled might be signaled via EXINAL_ILLEGAL_AXIS =
14092 or BSAL_SYSERRCHAN_RESET = 1011 instead of
EXINAL_TRANSFORM_PARAMETER = 14404.
Transformation-dependent error causes can be in: TRAORI: -
TRANSMIT:
• The current machine axis position is unsuitable for selection (e.g. selection in the pole)
(-> change position slightly).
• Parameterization via machine data has an error.