10.04
Remedy:
Program Continuation:
4014
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4016
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4017
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
The machine data required for the link module configuration must be the same on all
NCUs in the cluster.
Switch control OFF - ON.
Axis %1 defined several times in %2
%1 = String: MD identifier
%2 = String: Check and, if necessary, correct the following machine data with reference to
the data sheet:
An axis was assigned several times.
The axis can be a:
• Machine axis
• Link axis
• Axis in a container location
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Define a correct, unique axis assignment.
Switch control OFF - ON.
Axis %1 already used by NCU %2
%1 = Machine axis index
%2 = NCU number
An attempt was made to apply setpoints to one axis from several NCUs. Only occurs with
the NCU link system
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Define a correct, unique axis assignment.
Switch control OFF - ON.
Axis container %1, location %2 already used by NCU %3
%1 = Axis container number
%2 = Axis container location
%3 = NCU number
A multiple reference to the axis container location has been made via the logical axis table
(machine data: MN_AXCONF_LOGIC_MACHAX_TAB). With the NCU link, the multiple
reference may also have been made by another NCU in the NCU group.
Example: Container1 location1 was referenced twice incorrectly
• MN_AXCONF_LOGIC_MACHAX_TAB[0] = CT1_SL1
• MN_AXCONF_LOGIC_MACHAX_TAB[6] = CT1_SL1