1 Alarms
61349
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61350
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61351
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61352
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-450
Channel %1 block %2 Distance upper probe edge - measuring position = 0 for tool
radius measurement
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE971.
Parameter _TP[x,9] distance between upper edge and lower edge of tool probe equals 0;
relevant for radius measurement.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Feed, speed of tool measurement with rotating spindle in
_MFS not programmed
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE971.
Measuring feed and/or spindle speed of tool measurement with rotating spindle in GUD
variable _MFS[2] not specified.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Tool length or tool radius equal 0
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE971.
For the active tool, the length or radius equal zero.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Path for log file not permitted
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE106.
The specified path for the log file is incorrect.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
-
Clear alarm with the RESET key. Restart part program