1 Alarms
20121
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20122
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20123
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20124
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-328
Axis %1: Configuration error in compensation table %2
%1 = Axis name, spindle number
%2 = Compensation table
Interpolatory compensation with tables. The settings for the specified table are not
allowed. $AN_CEC_MAX >= $AN_CEC_MIN and $AN_CEC_STEP != 0 apply to system
variables. This table is switched off automatically.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Check and correct the char-
acteristic data in the compensation table. If the error cannot be found, the alarm can be
suppressed by switching off the table ($SN_CEC_TABLE_ENABLE) or switching off com-
pensation in the axis ($MA_CEC_ENABLE).
Clear alarm with the RESET key. Restart part program
Compensation table %1: invalid axis assignment
%1 = Compensation table
Interpolatory compensation with tables. The input or output axes assignment in the given
table is not allowed. $AN_CEC_INPUT_AXIS and $AN_CEC_OUTPUT_AXIS != 0 apply
to system variables. This table is automatically switched off.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Check and correct the axis
assignment in the compensation table. If the error cannot be found, the alarm can be sup-
pressed by switching off the table ($SN_CEC_TABLE_ENABLE) or switching off compen-
sation in the axis ($MA_CEC_ENABLE).
Clear alarm with the RESET key. Restart part program
Axis %1: different output assignment of multiplied tables
%1 = Axis name, spindle number
Interpolatory compensation with tables. The two tables whose outputs are to be multiplied
together have different output axes assigned to them. The compensation in this axis is
automatically switched off.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Check and correct the char-
acteristic data in the compensation table ($AN_CEC_OUTPUT_AXIS and
$AN_CEC_MULT_BY_TABLE).
If the error cannot be found, the alarm can be suppressed by switching off the compensa-
tion in the axis ($MA_CEC_ENABLE) or the tables, ($SN_CEC_TABLE_ENABLE).
Clear alarm with the RESET key. Restart part program
Axis %1: sum of compensation values too large
%1 = Axis name, spindle number
The sum of the compensation values from all tables assigned to the axis had exceeded
the limit value $MA_CEC_MAX_SUM and had to be limited. Contour errors could have
occurred as a result.
- Interface signals are set.
- Alarm display.
Check characteristic data of the compensation tables assigned to the axis.
Check characteristic curves in the tables ($AN_CEC).