Siemens SINUMERIK 840D Diagnostics Manual page 286

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
17055
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17060
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17070
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17080
Parameters:
1-286
Address frame components only with the keywords provided; program the scale factor
between the limits of 0.000 01 to 999.999 99.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 GUD variable not existing
%1 = Channel number
%2 = Block number, label
The required GUD variable was not found for a MEACALC procedure during read or write
access.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check whether all the GUDs were created for MEACALC.
DEF CHAN INT _MVAR, _OVI[11]
DEF CHAN REAL _OVR[32], _EV[20], _MV[20], _SPEED[4], _SM_R[10], _ISP[3]
DEF NCK REAL _TP[3,10], _WP[3,11], _KB[3,7], _CM[8], _MFS[6]
DEF NCK BOOL _CBIT[16]
DEF NCK INT _CVAL[4].
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 requested data area too large
%1 = Channel number
%2 = Block number, label
The maximum memory space of 8 KB available for a symbol has been exceeded.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Reduce array dimensions.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 data is write-protected
%1 = Channel number
%2 = Block number, label
An attempt was made to write to a write-protected variable (e.g. a system variable).
Safety Integrated: Safety system variables can only be modified from the safety SPL pro-
gram.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 %3 value below lower limit
%1 = Channel number
%2 = Block number, label
%3 = MD