Channel %1 block %2 Permissible dimensional difference exceeded
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE994
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
The difference between actual and setpoint value is larger than tolerance parameter
_TDIF, tool data are not corrected.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Max. no. of characters per line exceeded
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE105
Insufficient number of characters per line.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Increase the value in _PROTFILE[1]
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Variable column width not possible
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE105.
Unable to generate variable column widths, as no header available.
A fixed column width of 12 characters is used.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Complete the header in _PROTVAL[0].
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Insufficient column width
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE105.
The value to be logged is larger than the column width.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Adjust _PROTFORM[5] or change the header at variable column width.
Clear alarm with the RESET key. Restart part program