10.04
Reactions:
Remedy:
Program Continuation:
75050
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75051
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75060
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Alarm display.
- NC Stop on alarm.
The part program can be continued with NC start. The overlaid motion then returns to the
control distance.
Clear alarm with the Delete key or NC START.
Channel %1 wrong MD configuration, error code %2
%1 = Channel number
%2 = Error code
Incorrect configuration in MD $MA_CC_MASTER_AXIS
Error code = 2: This axis indicated in the alarm message or the CC_Master axis is a spin-
dle.
Error code = 4: Coupling between rotary and linear axes impermissible.
Error code = 8: Coupled axes must not be exchanged between channels.
- Interpreter stop
- Alarm display.
Check machine data.
Clear alarm with the RESET key. Restart part program
Channel %1 CC_COPON CC_COPOFF error code %2
%1 = Channel number
%2 = Error code
Error code = 1: Wrong argument programmed
Error code = 10: An axis for which no coupling has been defined, was programmed in
CC_COPON (axis identifier).
Error code = 20: Too many arguments programmed.
Error code = 100: Internal error
Error code = 200: Internal error
- Interpreter stop
- Alarm display.
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 tolerance window exceeded axis %2
%1 = Channel number
%2 = Axis name
The actual position value difference between the CC_Slave axis indicated in the alarm
message and its CC_Master axis is outside the configured tolerance window.
- NC Start disable in this channel.
- Alarm display.
- NC Stop on alarm.
Check configured tolerance window.
Compare dynamic response settings of coupled axes.
Check mechanical components of axes.
Clear alarm with the RESET key. Restart part program