Siemens SINUMERIK 840D Diagnostics Manual page 308

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
18202
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
18203
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
18204
Parameters:
Definitions:
Reactions:
1-308
An attempt was made to use a curve table whose table number is not known in the sys-
tem \par.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Change the table number in the program instruction or define the curve table with the
desired table number.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table: instruction CTABEND without CTABDEF not
allowed
%1 = Channel number
%2 = Block number, label
The CTABEND instruction, which is used to terminate the definition, has been pro-
grammed in the program without starting a curve table definition with CTABDEF, or the
CTABDEF and CTABEND instructions were not programmed in the same program level.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remove the CTABEND command or add the CTABDEF(..) command at the appropriate
program location. The CTABDEF and CTABEND instructions must be programmed in the
same program level (main or subprogram). Start the program again.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table: instruction CTABDEF not within CTABDEF
%1 = Channel number
%2 = Block number, label
In the program, the instruction CTABDEF that starts the definition of curve tables, is pro-
grammed within the definition part of a curve table. This is not allowed, as the current
curve table must be completed with CTABEND first.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remove command CTABEND from program or insert instruction CTABDEF (..) in the rel-
evant program position. Instructions CTABDEF and CTABEND must be programmed in
the same program level (main program or subroutine). Restart the program.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table: instruction SUPA not within CTABDEF
%1 = Channel number
%2 = Block number, label
G code SUPA is not allowed for the definition of a curve table, as it triggers a preprocess-
ing stop.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Advertisement

Table of Contents
loading

Table of Contents