10.04
380501
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
380502
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
380503
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
400102
Definitions:
Reactions:
Remedy:
Program Continuation:
400103
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
PROFIBUS DP: fault on bus %1 slave %2, code %3, time %4
%1 = Bus number
%2 = Slave address
%3 = Fault value of the drive (P945)
%4 = Fault time of the drive (P948)
Contents of the fault memory of the assigned slave.
- Alarm display.
See drive documentation for fault codes/fault values.
Alarm display showing cause of alarm disappears. No further operator action necessary.
PROFIBUS DP: bus %1, slave %2 configuration changed
%1 = Bus number
%2 = Slave address
The PB bus configuration has changed.
Causes:
• Initial start-up
• New PB slave recognized on the bus
- Interface signals are set.
- Alarm display.
In order to operate the bus with the new configuration, an additional restart will be
required.
Switch control OFF - ON.
PROFIBUS DP: bus %1 configuration changed
%1 = Bus number
A new SDB2000 with a modified configuration was provided.
The new settings will be activated only at the next ramp-up of PROFIBUS.
- Interface signals are set.
- Alarm display.
In order to operate the bus with the new configuration, an additional restart will be
required.
Switch control OFF - ON.
Delete DB 2 in the PLC and restart
The DB created by the basic program and the existing DB differ in size.
- Alarm display.
Displayed DB must be deleted via STEP7. Possibly max. program size of the user pro-
gram exceeded.
Internal
Delete DB 3 in the PLC and restart
The DB created by the basic program and the existing DB differ in size.
- Alarm display.
Displayed DB must be deleted via STEP7. Possibly max. program size of the user pro-
gram exceeded.
Internal