Siemens SINUMERIK 840D Diagnostics Manual page 391

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Remedy:
Program Continuation:
27024
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
27030
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- NC Stop on alarm.
- Channel not ready.
Trigger a "Deceleration on the current limit" and activation of the timer for a switchover
after STOP A (see MD $MA_SAFE_PULSE_DISABLE_DELAY).
Eliminate causes of alarm "Tolerance for safe standstill exceeded" or "STOP F triggered"
(see description of these alarms).
Switch control OFF - ON.
Axis %1 stop A triggered
%1 = Axis number
This alarm follows an
• Alarm 27011 "Safe velocity exceeded" (when configured as such in
$MA_SAFE_VELO_STOP_MODE, $MA_SAFE_VELO_STOP_REACTION)
• Alarm 27013 "Safe braking ramp exceeded",
• Alarm 27023 "Stop B triggered"
• unsuccessful test stop.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Trigger a "Pulse suppression".
Eliminate causes of
• alarm "Save velocity exceeded",
• alarm "Safe braking ramp exceeded",
• alarm "Stop B triggered"
• unsuccessful test stop
(see description of these alarms).
Switch control OFF - ON.
Axis %1 function not supported on this 611D module
%1 = Axis number
SINUMERIK Safety Integrated can be used only with the 611D Performance control mod-
ules with 2 measuring circuits per drive and cutoff relay. An attempt has been made to
activate a safety function although no such module is plugged in.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Replace module or switch off safety functions in MD $MA_SAFE_FUNCTION_ENABLE.
Switch control OFF - ON.
1 Alarms