10.04
16918
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16919
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16920
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16921
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16922
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 for action %2<ALNX> all channels must be in reset state
%1 = Channel number
%2 = Action number/action name
All channels must be in the initial setting in order to carry out the action! (For example, for
machine data loading)
- Alarm display.
Either wait until the channel status is aborted or press the Reset key.
Clear alarm with the Delete key or NC START.
Channel %1 action %2<ALNX> is not allowed due to a pending alarm
%1 = Channel number
%2 = Action number/action name
This action cannot be performed due to an alarm, or the channel is in fail.
- Alarm display.
Press RESET key.
Clear alarm with the Delete key or NC START.
Channel %1 action %2<ALNX> is already active
%1 = Channel number
%2 = Action number/action name
An identical action is still active.
- Alarm display.
Wait until the first procedure is terminated or abort with Reset and repeat the operation.
Clear alarm with the Delete key or NC START.
Channel %1 mode group %2 machine data: channel/mode group assignment not
allowed or assigned twice
%1 = Channel number
%2 = Mode group number
On powering up, an illegal channel/mode group assignment was detected.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check machine data
ASSIGN_CHAN_TO_MODE_GROUP.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Channel %1 subprograms: action %2<ALNX> maximum nesting depth exceeded
%1 = Channel number
%2 = Action number/action name
Various actions can cause the current procedure to be interrupted. Depending on the
action, asynchronous subroutines are activated. These asynchronous subroutines can be
interrupted in the same manner as user programs. Unlimited nesting depth is not possible
for asynchronous subroutines due to memory limitations.
1 Alarms
1-271

Advertisement

Table of Contents
loading

Table of Contents