Siemens SINUMERIK 840D Diagnostics Manual page 82

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
7500
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
8000
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
8010
Parameters:
Definitions:
Reactions:
1-82
The interface for OEM transformations has changed incompatibly in the system.
- NC not ready.
- Channel not ready.
- Interface signals are set.
- Alarm display.
- Alarm reaction delay is canceled.
Load the new compile cycle version
Clear alarm with the RESET key in all channels. Restart part program.
Block %1 invalid protection level for command %2 (protection level act.: %3 prog.:
%4)
%1 = Block number
%2 = Programmed command
%3 = Current protection level of the command
%4 = Programmed protection level of the command
On assigning a protection level for a parts program command via REDEF command
• an impermissible parts program command has been programmed
• a protection level has been programmed that is logically smaller (larger in value) than
the protection level currently applicable for this command.
• the relevant definition file has not been protected sufficiently against write access. The
write protection of the file must be at least as high as the highest protection level that has
been assigned to a parts program command in this definition file.
- Alarm display.
Modify definition files /_N_DEF_DIR/_N_MACCESS_DEF or /_N_DEF_DIR/_N_UAC-
CESS_ DEF. Please see the Siemens Programming Guide or the OEM documentation
for the language commands permissible for the relevant system configurations.
Clear alarm with the RESET key. Restart part program
Channel %1 option 'user interrupt programs' not set
%1 = Channel number
The input signals of NCK inputs are required in order to activate the interrupt routines and
rapid lift from contour. This function is not included in the basic version and must be retro-
fitted when needed.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Do not use rapid interrupt
inputs or contact the machine manufacturer with a view to retrofitting this option!
Clear alarm with the RESET key. Restart part program
Option 'activation of more than %1 axes' not set
%1 = Number of axes
More machine axes have been defined through the channel-specific MD 20070
AXCONF_MACHAX_USED than are allowed in the system.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
 Siemens AG, 2004. All rights reserved