Siemens SINUMERIK 840D Diagnostics Manual page 460

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
61601
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61602
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61603
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61604
Parameters:
Definitions:
1-460
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Adjust _CVAL entry with the number of available probe or calibration block data fields.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 finished-part diameter too small
%1 = Channel number
%2 = Block number, label
An incorrect finished-part diameter has been programmed. Alarm triggered by following
cycles: CYCLE94, CYCLE96.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 tool width incorrectly defined
%1 = Channel number
%2 = Block number, label
Plunge cutter is larger than the programmed groove width. Alarm triggered by following
cycle: CYCLE93.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 groove form incorrectly defined
%1 = Channel number
%2 = Block number, label
Radii/chamfers at the groove base do not match the groove width. Face groove on a con-
tour element running parallel to the longitudinal axis is not possible. Alarm triggered by
following cycle: CYCLE93.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 active tool violates programmed contour
%1 = Channel number
%2 = Block number, label
Contour violation in the relief cut elements due to the tool clearance angle of the tool
used. Alarm triggered by following cycle: CYCLE95.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Advertisement

Table of Contents
loading

Table of Contents