Siemens SINUMERIK 840D Diagnostics Manual page 645

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Remedy:
Program Continuation:
380022
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
380040
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Create the user-specific SDB1000 and load it on the control system, or select and activate
it via MD 11240 standard SDB1000. Restart the NC. If the error occurs the next time the
NC is switched on, the SDB1000 which was loaded contains an error and must be created
again.
Clear alarm with the Delete key or NC START.
PROFIBUS DP: configuration of DP master bus %1 has been changed
%1 = Number of the affected bus
The PROFIBUS configuration on the DP master was changed during operation, e.g. by
downloading a new hardware configuration via Step7. Since it is possible that the cycle
data have changed, operation cannot be continued and a warm start is required.
If the DP master functionality is within the PLC (as on the 840Di), the PLC will have been
stopped for the download and alarm 2000 (PLC sign-of-life) output.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
NCK restart
If the error cannot be eliminated by this procedure, please make a note of the error text
and contact the control system manufacturer.
Switch control OFF - ON.
PROFIBUS DP: bus %3, configuration error %1, parameter %2
%1 = Cause of the error
%2 = Parameter
%3 = Number of the affected bus
The PROFIBUS DP was not generated in SDB1000 in accordance with the configuration
specifications of the NC in use.
Overview: Cause of the error, Par 1:
• 01 = SDB contains slave without diagnostics slot, Slave address
• 02 = SDB contains too many slot entries, Identifier
• 03 = SDB contains no equidistance data, No fct.
• 20 = SDB contains too many slaves, number of slaves.
• 21 = SDB missing or contains invalid data, error code.
• 22 = SDB configuration data erroneous, slave address, error code
• 23 = reserved
• 24 = reserved
• 25 = reserved
• 26 = reserved
• 27 = reserved
• 28 = reserved
• 29 = reserved
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
1 Alarms