Siemens SINUMERIK 840D Diagnostics Manual page 428

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
61180
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61181
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61182
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61183
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-428
Channel %1 block %2 no name assigned to swivel data block, although MD
$MN_MM_NUM_TOOL_CARRIER > 1
%1 = Channel number
%2 = Block number, label
Although there are several swivel data blocks, no unique names were assigned. Alarm
triggered by following cycles: CYCLE800.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Assign unique names for swivel data blocks.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 NCK software version insufficient (missing TOOLCARRIER
functionality)
%1 = Channel number
%2 = Block number, label
Swivelling is not possible with the current NCK software version. Alarm triggered by fol-
lowing cycles: CYCLE800.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Upgrade NCK software.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 name of swivel data block unknown
%1 = Channel number
%2 = Block number, label
the specified name of the swivel data block is unknown. Alarm triggered by following
cycles: CYCLE800, E_TCARR.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check the name of the swivel data block.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 retraction mode GUD7 _TC_FR beyond value range 0... 2
%1 = Channel number
%2 = Block number, label
The retraction mode value lies outside of the valid range. Alarm triggered by following
cycles: CYCLE800.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check installation and start-up of the swivel cycle CYCLE800.
Clear alarm with the RESET key. Restart part program
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Advertisement

Table of Contents
loading

Table of Contents