1 Alarms
Reactions:
Remedy:
Program Continuation:
4225
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4230
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4240
Parameters:
Definitions:
Reactions:
1-50
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. The spindle number is stored
in the axis-specific MD array 35000 SPIND_ASSIGN_TO_MACHAX. The channel to
which this machine axis/spindle is assigned is listed in the machine axis index. (The
machine axis number is given in the channel-specific MD array 20070
AXCONF_MACHAX_USED).
Switch control OFF - ON.
Channel %1 axis %2 declaration as rotary axis missing
%1 = Channel number
%2 = Axis name, axis number
The modulo functionality requires a rotary axis (positions in [deg],.).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Set MD "IS_ROT_AX".
Switch control OFF - ON.
Channel %1 data alteration from external not possible in current channel state
%1 = Channel number
It is not allowed to enter this data while the part program is being executed (e.g. setting
data for working area limitation or for dry run feedrate).
- Alarm display.
The data to be entered must be altered before starting the part program.
Clear alarm with the Delete key or NC START.
Runtime overflow for IPO cycle or position controller cycle, IP %1
%1 = Program location
The settings for the interpolation and position control cycle were modified before the last
power-up such that too little computing time is now available for the requisite cyclic task.
The alarm occurs immediately after power-up if too little runtime is available even when
the axes are stationary and the NC program has not started. However, task overflow can
occur only when computation-intensive NC functions are called during program execu-
tion.
- NC not ready.
- The NC switches to follow-up mode.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Alarm reaction delay is canceled.