1 Alarms
61266
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61267
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61301
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61302
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-444
Channel %1 block %2 Direction of machining impermissible
%1 = Channel number
%2 = Block number, label
In face milling, the delimitations and the direction of machining do not match.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Select another direction of machining.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Plane infeed too large, residual corners are left over
%1 = Channel number
%2 = Block number, label
In face milling, the plane infeed must not exceed 85%.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Select a smaller plane infeed, as otherwise residual corners will be left over.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 measuring probe does not switch
%1 = Channel number
%2 = Block number, label
The measuring distance was completely traversed but no switching signal was generated
at the measuring input specified by MD 9750or MD 9751.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check measuring probe connection
Set a longer measuring distance via MD 9752, 9753, 9754, 9755
When measuring an edge: Position closer to the edge
For spigots/holes: Position roughly over the middle
Check value for spigot/hole diameter
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 measuring probe collision
%1 = Channel number
%2 = Block number, label
The measuring probe collided with an obstacle when being positioned.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check spigot diameter (may be too small)
Check measuring distance (may be to long)
Clear alarm with the RESET key. Restart part program
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04