Siemens SINUMERIK 840D Diagnostics Manual page 487

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
75608
Definitions:
Reactions:
Remedy:
Program Continuation:
75609
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75610
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Interface signals are set.
- Alarm display.
Switch the control to the AUTO operating mode and restart resynchronisation.
Clear alarm with the Delete key or NC START.
Channel %1 RESU: NC memory limit reached, RAM type %2
A memory limit was reached on writing to file cc_resu.mpf. The possible area for return
traveling is shortened.
RAM type = 1: File cc_resu.mpf is created in the buffer memory (SRAM). The buffer mem-
ory is therefore full. If the buffer memory is used and if alarm 75608 with RAM type 1 is
output, system alarm 6500 will be output simultaneously.
RAM type = 2: The memory limit was reached on creating file cc_resu.mpf in the dynamic
memory (DRAM part program memory).
- Alarm display.
RAM type = 1: Increase size of buffer memory ($MN_MM_USER_MEM_BUFFERED) or
the available space in the buffer memory, e.g. by unloading unused parts programs. Alter-
natively the ring buffer can be decreased via MD $MC_RESU_RING_BUFFER_SIZE.
Clear alarm with the Delete key or NC START.
Channel %1 RESU: POS axis not permitted, axis type %2, block no. %3
%1 = Channel number
%2 = Axis type
%3 = Block number
A geometry axis is traversed as positioning axis at active CC_RREPRE.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
In order to traverse a geometry axis as positioning axis, RESU must be switched off tem-
porarily (with CC_PREPRE(0)) or completely. In order to make the internal axis state
change from the geometry axis as positioning axis after traversing, a block without travel-
ing motion must be programmed, if required: e.g. X=IC(0)
Clear alarm with the RESET key. Restart part program
Channel %1 RESU: NC start currently not possible
While RESU is active, no NC START must be performed in certain situations. If NC
START is confirmed nevertheless, execution will be blocked and alarm 75610 will be dis-
played. This applies in the following situations:
On requesting return traveling: NC START is blocked when return traveling program
cc_resu.mpf has been created and selected.
After having triggered continuation under NC STOP condition: as long as the internally
started block search or the finally started Asup cc_resu_bs_asup.spf is running.
- Interface signals are set.
- Alarm display.
Wait for completion of the current internal procedure. Then delete the alarm with NC
START and continue
Clear alarm with NC START or RESET key and continue the program.
1 Alarms
1-487

Advertisement

Table of Contents
loading

Table of Contents