Multi functional protection ied

Advertisement

Signal
4.2.9
Signal monitoring points in DPOS01
DPOS01(Function ID: 512001)
Element ID
Name
8003011DE0
DEV1PLCCTRLFAIL
3103011001
DPOS01_3PH_STATE
3103011FE5
DPOS01_APH_STATE
3103011FEA
DPOS01_BPH_STATE
8603011F7B
DPOS01_CNT_CS07
0003011D91
DPOS01_CNT_SEL
3203011D20
DPOS01_CNT_VAL
3103011FEF
DPOS01_CPH_STATE
8B03011F79
DPOS01_CTR_SGU
8903011F99
DPOS01_CTR_SGUCN
8203011E8B
DPOS01_EC_F_CS
8103011E9A
DPOS01_ECF_FCT_EIS
0003011D97
DPOS01_EX_BO_OPOK
8003011E93
DPOS01_EX_CMP
8F03011F5E
DPOS01_EX_CMP_TMO
8903011F9E
DPOS01_EX_CMP_TMOCN
8603011E91
DPOS01_EX_FFL
8503011E8F
DPOS01_EX_SFL
8003011E81
DPOS01_FEC_OK_CS
8103011DD0
DPOS01_FEX_BO
8403011F45
DPOS01_FLT_DET1
8A03011DC4
DPOS01_FSL_BO_FLG
8A03011F81
DPOS01_FSL_CS19
3103011D01
DPOS01_LCD_ST
3103011D00
DPOS01_MMC_ST
8903011DC0
DPOS01_NSL_BO_FLG
8603011F7E
DPOS01_NSL_CS07
8103011E82
DPOS01_OEC_OK_CS
8203011DD3
DPOS01_OEX_BO
8603011DC6
DPOS01_OSL_BO_FLG
8803011F73
DPOS01_OSL_CS41
8603011F8B
DPOS01_RST_CS07
0003011F57
DPOS01_RST_SIG
8503011F87
DPOS01_SE_RCV_RMTCN
8503011F8A
DPOS01_SE_RCV_RMTRT
8003011E76
DPOS01_SLD_CS
8003011F67
DPOS01_SLD_CS04
8103011F68
DPOS01_SLD_CS05
8203011F69
DPOS01_SLD_CS06
8A03011F86
DPOS01_SLD_CSCN
8A03011F89
DPOS01_SLD_CSRT
0003011D90
DPOS01_SLD_RPT
8E03011F5D
DPOS01_SLD_TMO
8A03011F9D
DPOS01_SLD_TMOCN
8103011E7B
DPOS01_SLF_CS
8703011E98
DPOS01_SLF_FCT_EIS
8803011F9B
DPOS01_SLF_FCT_F03CN
8703011F9C
DPOS01_SLF_FCT_F04CN
8303011F9A
DPOS01_SLF_FCT_F07CN
8503011F65
DPOS01_SLF_FCT_FLG05
8803011F6C
DPOS01_SLF_FCT_FLG07
Description
DEV1PLCCTRLFAIL
DPOS01 3ph_state
DPOS01 aph_state
DPOS01 bph_state
DPOS01 count change selected fail condition signal
DPOS01 count change selected signal(stSeld) for SAS
DPOS01 count value
DPOS01 cph_state
DPOS01 selected signal
DPOS01 count change selected signal
DPOS01 execute command fail condition signal
DPOS01 execute command fail factor signal except interlock/synchronism check
DPOS01 execute binary output signal for SAS
DPOS01 execute complete signal
DPOS01 timeout after execute completion
DPOS01 count change timeout after execute completion
DPOS01 execute fail signal by fixedlogic
DPOS01 execute success signal by fixedlogic
DPOS01 off direction execute command OK condition signal
DPOS01 off direction execute binary output signal
DPOS01 Faulty Detected (3 phase concentration data only)
DPOS01 off direction select binary output signal
DPOS01 select receive open signal check answer
DPOS01 state for LCD
DPOS01 state for MIMIC
DPOS01 select binary output signal
DPOS01 select receive signal check answer
DPOS01 on direction execute command OK condition signal
DPOS01 on direction execute binary output signal
DPOS01 on direction select binary output signal
DPOS01 on direction select condition signal 41
DPOS01 reset time selected fail condition signal
DPOS01 reset time signal
DPOS01 count change selected fail condition signal check
DPOS01 reset time selected fail condition signal check
DPOS01 selected condition signal
DPOS01 selected condition signal 04
DPOS01 selected condition signal 05
DPOS01 selected condition signal 06
DPOS01 count change selected condition signal
DPOS01 reset time selected condition signal
DPOS01 selected signal(stSeld) for SAS
DPOS01 time out after selected
DPOS01 count change time out after selected
DPOS01 no direction select fail condition signal
DPOS01 select fail factor signal except interlock/synchronism check
DPOS01 count change select fail factor signal by fixedlogic 03
DPOS01 count change select fail factor signal by fixedlogic 04
DPOS01 count change selected timer for a check
DPOS01 select fail factor signal by fixedlogic 05
DPOS01 selected timer for a check
- 550 -